4 Windows Driver
• Wrong: Overspeed is set to 2. The application requests 38400, the result is 76800. Even
when this is below the maximum speed of the modem, it does not recognize this speed in
many cases. Operation is not possible.
• Wrong: Windows searches for Modems at certain speeds. Modem detection may fail, because
of wrong settings.
• Correct: The application is limited to 19200. Overspeed my be 6 or 12 to get 115200 or even
230400 with a modern modem.
Automatic Software Flow Control
Figure 20: Auto XON/XOFF
This panel configures the On-Chip Software Flow Control provided by the UART. Only some
UART types support the Flow Control directly on the chip. Use the 16950 emulation to allow rich
possibilities.
To get access to this panel configure Software Flow Control in the Standard Port Settings (see 4.2.3),
and leave it enabled in the driver.
July 2011 VScom Industrial Card User Manual 34