3 Hardware Configuration
For BIAS there is a natural rule. The BIAS of positive (+) and negative () lines are either both
activated, or both not used.
Right below the crystal is the compatibility speed header JP1. This is used to configure the
maximum bitrate of the serial ports.
Pins max. Bitrate Remark
2–3 921,600 Default configuration
1–2 115,200 Compatibility option
Table 11: JP1 for Speed
The mentioned pins have to be connected by a cap to configure the operation mode. Make sure
there is a cap placed in any of the two allowed positions, otherwise the port will not operate. When
the configuration has been changed, the driver for Windows has to learn this. In the Advanced
panel click on the “Check” button (4.2.2).
3.4 VScom 200I-SI UPCI
Besides the consequences of optical isolation and added surge protection, the VScom 200I-SI UPCI
card is configured and used in much the same way as the 200I card (3.3).
The operation mode is configured via the DIP switches S1 and S2 according to table 9 above.
Also resistors for Termination and BIAS option are built-in, configured by a block of jumpers J2
and J3 as of table 10 above. A jumper must be closed (both pins connected by a cap) to activate
the mentioned function.
Right below the crystal is the compatibility speed header JP1. This is used to configure the
maximum bitrate of the serial ports, see table 11 above. When the configuration has been changed,
the driver for Windows has to learn this. In the Advanced panel click on the “Check” button
(4.2.2).
3.5 VScom 400I UPCI
The connector CN1 harbors all signals of the serial ports, see section 8.2. The operation mode is
configured via the DIP switches S1 to S4 according to table 12. In contrast to the 2-port cards,
here are six modes of RS 485. The new modes allow to control the RS 485 transmitter using signal
RTS
2
instead of the automatic ART.
2
This means by customers application
July 2011 VScom Industrial Card User Manual 17